Aurora AUP- 1001-TSB Uninterruptible Power Supply
High power density
Input power factor 0.99 with PFC
Maximum charging current can be expanded to 12A (Long run unit)
Intelligent fans peed regulation
Multiple communication interface: RS232 (USB/EPO/Relay card /SNMP card)
Multiple protection function: short-circuit, overload, overheat, battery overcharge and over discharge, output low voltage and fan fault alarm
Especificaciones
Physical
Dimension W×D×H: 191×460×720mm
Net weight: 71kg
Standards
Safety: IEC/EN 62040-1, IEC/EN 62477-1
EMC: IEC/EN 62040-2 (IEC 61000-4-2, IEC 61000 4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2)
Indicators
LED display: Line mode, Bat.mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
LCD display: Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature& Remaining battery backup time
Environment
Operating temperature: 0℃~40℃
Storage temperature: −25℃~55℃
Humidity range: 20~95%RH @ 0~40℃ (Noncondensing)
Altitude: <1500m, derating required when>1500m
Noise level: <58dB at 1 Meter
Capacity
10000VA/9000W
Frequency
Frequency range: 40〜70Hz (50/60Hz Auto-Sensing)
Alarm
Battery mode: Beeping every 4 seconds
Battery low: Beeping every second
Overload: Beeping twice every second
Fault: Continuously beeping
Input
Nominal voltage: 208/220/230/240Vac
Input voltage range: 110〜286Vac
Power factor: ≥0.99
Bypass voltage range: Max.voltage: 230〜264Vac, Min.voltage: 176〜220Vac
Output
Output voltage: 208/220/230/240Vac
Voltage regulation: ±1%
Power factor: 0.9
Output frequency: Line mode: 46〜54Hz or 56~64Hz, Bat. mode: (50/60±0.1%)Hz
Crest factor: 3:1
Harmonic distortion (THDv): ≤3% Linear load, ≤5% Non linear load
Transfer time: AC mode to Bat.mode: 0ms, Inverter to Bypass: 4ms (Typical)
Output waveform: Pure Sinewave
Overload: Line mode: Load≤105% long time
running;≤125% last 10min;≤130% last 30s; >
130% turn to bypass mode immediately, Bypass mode: 40A (Breaker)
Efficiency: up to 93.5%
Battery
Battery voltage: 240Vdc
Capacity (Standard unit): 9Ah/12V (7Ah/12V optional)
Typical recharging time: 6〜8 hours (To 90% of full capacity)
Charging current (Max.): 1.35A (Standard unit); Long run unit Max.current 8A (Charging current can beset according to battery capacity)
Documentación
Comparar
¿Desea comprar?
¿Quiere comprar pero no sabe por dónde empezar?
Contáctanos
Video Surveillance
Server, Storage & Workstations
Structured Cabling
Racks and Cabinets
Power Systems
Access Control
Network Audio
Intercom Systems
Communication Networking equipment
Ficha técnica del producto
AUP- 1001-TSB – Aurora Communication Technologies
Inicio
Power Systems
UPS & Battery
AUP- 1001-TSB