Communication
1 X RJ-45 10/100 Mbps ethernet port, PoE standard, 100m max distance. Wire Spec 100m max distance, Cat5 or better.
1 X RS-485 used to communicate to IO expansion boards. Wire Spec 600m max distance,
2 Conductors stranded, twisted pair 22 AWG, shielded
Power Supply
1 x 12-13.8VDC input lA-5.SA depending on attached devices/locks. Power requirements guide available. Generic 12VDC SA power supply available Power.
1 x battery backup terminal.12VDC 7AH recommended.
Inputs
8 X Digital input wire spec 152m Max Distance, 2 Conductors stranded 22 AWG, Shielded.
2 X Wiegand ports. Wire Spec 152m Max Distance, 6 Conductors stranded not twisted, 24 AWG, shielded.
Outputs
8 X solid state relays up to 30V @ 500mA (additionally relay options such as normally closed available upon request)
1 X 12V out up to 12V - 300mA. Wire Spec 152m Max Distance, 2 conductors stranded 18 AWG.
2 x Wiegand ports. Wire spec 152m (500’) Max Distance, 6 conductors stranded not twisted, 24AWG, shielded.
MISC
Super capacitor maintains data and time up to 1 month without power. Photo-resistive tamper sensor.
Piezo buzzer. Automatic DST switch.
Software
Door controller is programmed and monitored from PN server software.
Software can be hosted by Aurora controls, Security integrator or via local/ remote Windows PC/ Server.
Elevator