AUP- 1010-RS

Aurora AUP- 1010-RS Uninterruptible Power Supply

  • 1/1 Phase, 10kVA / 10kW Capability Rack design
  • Online double conversion with full digital control
  • Smart charger design for optimized battery performance
  • maximum charging current can be expanded to 12A (Long run unit)
  • Emergency power off function (EPO)
  • ECO mode operation for energy saving
  • Generator compatible
  • Hot-Swappable battery design
  • Intelligent fan speed regulation
  • Versatile LCD human-computer interface
  • Internal SNMP card
  • 2- year warranty

Specifications


Specifications
Input: Output 1-in: 1-out
Rated Capacity 10kVA / 10KW
Mains Input
Rated Voltage 200/208/220/230(Default)/240Vac
Input Voltage Range 110-300Vac (110-176Vac @ 50% load / 176-300Vac @ 100% load)
Input Frequency Range 40-70Hz
Input Power Factor >0.99
Harmonic distortion (THDi) < 3%
Input Connection Terminal (L+N+G)
Battery
Battery Number N / A
Nominal DC Voltage
  • ±96/108/120Vdc
  • 16 pcs default
  • ≤9AH or 20 pcs no power derating
  • >9AH and 18 pcs output power factor 0.9
  • >9AH and 16 pcs output power factor 0.8
Charging Current (max) 14A
Hot Swappable Included
Ext. Battery Connector. Included
Output
Rated Voltage 200/208/220/230(Default)/240Vac
Rated Frequency
  • 50/60Hz ± 10% (Line mode)
  • 50/60Hz(default)
  • ±0.1% (Battery mode)
Output Power Factor 1
Waveform Pure Sinewave
Harmonic distortion (THDv) ≤1% Linear load, ≤3% Nonlinear load
Overloud conditions for Online
  • 105%~110%: UPS to bypass after 60 min when the utility is normal,
  • 110%~125%: UPS to bypass after 10 min when the utility is normal
  • 125%~150%: UPS to bypass after 1 min when the utility is normal
  • >150%: UPS to bypass after 0.2 sec when the utility is normal
Overloud conditions for Battery
  • 105%~110%: UPS after 10 min shut down,
  • 110%~125%: UPS after 1 min shut down
  • 125%~150%: UPS after 10 sec shut down
  • >150%: UPS after 0.2 sec shut down
Overloud conditions for Bypass
  • 105%~130%: Only Overload alarm
  • 130%~150%: UPS after 10 min shut down
  • 150%~200%: UPS after 1 min shut down
  • >200%: after 0.2 sec shut down
Transser Time AC <-> Battery: 0ms, Inverter <-> bypass: 0ms
Voltage Regulation ±1%
Output Voltage Regulation (Dynamic) ±5%
Online Efficiency (up to) 0.955
Economy mode efficiency 0.98
Current Crest 3:1
Indicator
LED display Line mediatory mode, ECO mode, Bypass mode, Battery low voltage, Overload & UPS fault
LCD display Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage, Inner temperature& Remaining battery backup time
Environment
Operating conditions 0°C ~40°C (40°C ~ 50°C derating to 80% load)
Storage conditions −25°C ~ 55°C (without batteries)
Relative Humidity 0~95%RH (Non -condensing)
Operating Altitude 0~1000 meters Normally operate; 1000~3000 meters Derating
Protection Class IP20
Audible Noise ≤50dB @ 1 Meter
Others
Dimensions (L * W * H) 440 * 671.5 * 131 mm
Weight 26 Kg
Certifications
  • Safety: CB: IEC 62040-1:2017, CE-LVD: EN 62040-1:2008+A1:2013
  • EMC: IEC 62040-2-2016, EN 62040-2-2018 C2
Communications RS232 (USB/EPO/Dry contact /SNMP card)
Protection function Short-circuit, Overload, Overheat, Battery, Overcharge and Over-discharge, Output low voltage, and Fan fault alarm
Topology Double Conversion On-Line
Cooling Fan cooled

Documentations

Please download the technical documents here